Fire Chief’s Regulation No. 4 (REG 4)
What is LAFD Reg 4?
Regulation 4 (Reg 4) is a Los Angeles Fire Department–mandated testing program that requires annual and 5‑year inspections of fire‑life safety systems such as fire pumps, sprinklers, standpipes, alarms, and more. Only certified testers can perform Reg 4 tests.
Reg 4 was created in the 1960s after several major fires — including the Olive Street fire — revealed that many buildings had fire protection systems that were installed but never tested. LAFD created Reg 4 to ensure systems are regularly inspected, maintained, and ready for real emergencies.
What systems require Reg 4 testing?
Automatic Closing Fire Assemblies
Automatic Elevator (Phase I & Phase II)
Automatic Sprinkler System (CZFP Cesar Santos Certified Tester)
Basic Fire Alarm Systems Only
Complex Fire Alarm and Supervising Station Alarm Systems
Stored Electrical Energy Systems Only
Supervising Station Alarm
Class I Standpipe
Class II Standpipe
Class III Standpipe
Combined Standpipe and Automatic Sprinkler System (CZFP Cesar Santos Certified Tester)
Elevator Witness Only
Emergency Generator and Battery Systems
Fire Escape Assemblies
Fire Pumps (CZFP Cesar Santos Certified Tester)
Gas Detection
Mechanical Smoke Proof Enclosures
Pressurized Stair-shaft
Smoke Evacuation (909/905)
How often is Reg 4 testing required?
Annually: Fire pump, alarms, emergency power, and other life‑safety systems
Every 5 years: Automatic Sprinkler Systems, Standpipes Systems flow tests
Who is allowed to perform Reg 4 testing?
Only LAFD‑certified Reg 4 testers are authorized to perform and submit Reg 4 inspections. Certification ensures the tester understands LAFD procedures, NFPA standards, and proper testing methods.
What happens if my building fails a Reg 4 test?
You will receive a deficiency report outlining what needs to be corrected. After repairs are completed, a certified tester performs a re‑test and submits the passing certification to LAFD.
Do you submit the certification to LAFD?
Yes. After testing is complete, we submit all required documentation and certification directly to the LAFD Reg 4 portal on your behalf.
Will I receive documentation for the fire department?
Yes. We provide full LAFD Reg 4 reports and defects list.
What are common issues/defects found during a Reg 4 testing?
Missing or painted sprinkler heads
Corroded or leaking piping
Closed or partially closed valves
Damaged or obstructed FDCs
Failed Fire Pump performance
Blocked standpipe outlets
Faulty alarms or supervisory devices
Can you repair defects you find?
Absolutely. We provide repair quotes and fast turnaround.
At Czar Fire Protection INC, we are Reg 4 certified specializing in,
Fire Pumps
Automatic Sprinkler Systems
Combined Standpipes
How do I schedule a Reg 4 test?
You can contact us directly to schedule annual or 5‑year Reg 4 testing. We offer fast turnaround, clear reporting, and full LAFD compliance.